Key result
Extended pulsed-field ablation protocol fails to improve 12-month arrhythmia-free survival over standard dosing.
Why the study?
Key procedural aspects of pulsed-field ablation for atrial fibrillation, including the optimal number of applications per pulmonary vein, remain poorly defined and whether increasing lesion dose improves outcomes is unknown.
Does an extended pulsed-field ablation dosing protocol (12 applications per pulmonary vein) improve freedom from atrial arrhythmia recurrence compared to a standard protocol (8 applications) in patients with atrial fibrillation?
Cohort (n=240)
Yes
Does an extended pulsed-field ablation dosing protocol (12 applications per pulmonary vein) improve freedom from atrial arrhythmia recurrence compared to a standard protocol (8 applications) in patients with atrial fibrillation?
Absolute Event Rate: 79% vs 73%
p-value: p=0.433
Escalating pulsed-field ablation applications from 8 to 12 per pulmonary vein increases myocardial injury and lesion size but does not improve arrhythmia-free survival, suggesting standard dosing is sufficient.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Isenegger et al. (2026) conducted a cohort in Atrial Fibrillation (n=240). Extended pulsed-field ablation (PFA) protocol vs. Standard PFA protocol (8 applications per pulmonary vein) was evaluated on Freedom from atrial arrhythmia recurrence at 12 months after a 60-day blanking period (p=0.433). An extended pulsed-field ablation protocol of 12 applications per pulmonary vein did not significantly improve 12-month arrhythmia-free survival compared to a standard 8-application protocol (79% vs 73%, p=0.433).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: