Key result
The Toronto stentless porcine valve showed excellent early durability, but the cumulative incidence of repeated AVR increased to 34.4% at 15 years.
Why the study?
The study was conducted to examine the long-term durability of the Toronto stentless porcine valve in the aortic position.
What is the long-term durability and survival associated with the Toronto stentless porcine valve in patients undergoing aortic valve replacement?
Cohort (n=515)
Yes
What is the long-term durability and survival associated with the Toronto stentless porcine valve in patients undergoing aortic valve replacement?
Answers are grounded in this paper and cite their sources.
The Toronto stentless porcine valve provides excellent survival and durability in the first decade, but structural valve deterioration (primarily regurgitation) increases significantly after 10 years, requiring reoperation in over a third of patients by 15 years.
BACKGROUND AND AIM OF THE STUDY: The purpose of this study is to examine the long-term durability of the Toronto stentless porcine valve (SPV) in the aortic position (St Jude Medical, Minneapolis, MN). METHODS: We assessed the long-term clinical outcomes of 515 patients with aortic valve replacement (AVR) with the Toronto SPV from 1987 to 2001 at two centers, excluding early (<30 days) death. Median follow-up was 11.5 years (maximum 19.0 years). RESULTS: Average age was 64.2 ± 10.8 years, and females were 34% (173/515). The incidence of prosthesis-patient mismatch was low, 10.9%. Overall survival was 90.7 ± 1.3%, 75.4 ± 2.0%, and 56.8 ± 3.2% at 5, 10, and 15 years, respectively after surgery. Over the follow-up duration, 116 patients (23%) underwent repeated AVR: 90 for structural valve deterioration (SVD), 12 for endocarditis, 10 nonstructural valve dysfunction (10 aortic regurgitation due to aorta dilatation), and four for other reasons. The cumulative incidence of repeated AVR with death as a competing risk was 1.4% (95% confidence interval [CI], 0.6-2.7), 11.1% (95% CI, 8.4-14.2), and 34.4% (95% CI, 28.8-40.2) at 5, 10, and 15 years, respectively. Reoperative mortality was 5.2% (6/116). In SVD, the regurgitation type was dominant (82%). CONCLUSIONS: The Toronto SPV is associated with excellent survival and durability during the first decade of follow-up. However, regurgitation type of SVD increases from 10 years after operation with acceptable reoperative mortality. These findings may assist with prosthesis selection and reintervention strategy for failing stentless bioprosthesis.
No takes yet. Share an insight, caveat, or question.
Une et al. (2020) conducted a cohort in Aortic valve replacement (n=515). Toronto stentless porcine valve (SPV) was evaluated on Cumulative incidence of repeated AVR at 15 years (95% CI 28.8-40.2). The Toronto stentless porcine valve showed excellent early durability, but the cumulative incidence of repeated AVR increased to 34.4% at 15 years.
Synapse has enriched 10 related papers. Consider them for comparative context: