It is believed that the aging of insulating oils affects the electrostatic charging tendency (ECT) and dielectric dissipation factor (tan /spl delta/), but there is little hard evidence. We have investigated changes in ECT and tan /spl delta/ of insulating oils aged with oxygen at elevated temperature. We found that ECT and tan /spl delta/ increased with aging time. In some oils aged with a small amount of oxygen, ECT and tan /spl delta/ increased much more than in other oils aged with a large amount of oxygen. In yet other insulating oils, ECT and tan /spl delta/ showed a peak and then declined. Moreover, it was found that aged insulating oil close to the peak in tan /spl delta/ is very unstable. This result suggests that the methods of measurements of tan /spl delta/ of insulating oil prescribed in International Electrotechnical. Commission (IEC) 60247 and Japanese Industrial Standards (JIS) C2101 may be unsatisfactory. The reason is that since in these methods tan /spl delta/ is measured at elevated temperature (IEC 60247, 90/spl deg/C and JIS C2101, 80/spl deg/C), the quality of the insulating oil, especially aged oil, is changed during the measurement, resulting in an incorrect reading.
No takes yet. Share an insight, caveat, or question.
KANNO et al. (2001) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: