Key result
Saddle-shaped annuloplasty rings experienced significantly lower out-of-plane forces compared to flat rings, which showed force accumulation in anterior and commissural segments (P<0.05).
Why the study?
Does a saddle-shaped annuloplasty ring improve uniform systolic force distribution compared to a flat ring in a porcine model?
Does a saddle-shaped annuloplasty ring improve uniform systolic force distribution compared to a flat ring in a porcine model?
p-value: p=<0.05
Saddle-shaped annuloplasty rings minimize out-of-plane forces compared to flat rings, providing a biomechanical rationale for their use to potentially enhance the durability of mitral valve repair.
May support saddle-shaped rings for mitral annuloplasty force distribution; hypothesis-generating in porcine model, needs human validation.
BACKGROUND: New insight into the 3D dynamic behavior of the mitral valve has prompted a reevaluation of annuloplasty ring designs. Force balance analysis indicates correlation between annulus forces and stresses in leaflets and chords. Improving this stress distribution can intuitively enhance the durability of mitral valve repair. We tested the hypothesis that saddle-shaped annuloplasty rings have superior uniform systolic force distribution compared with a nonuniform force distribution in flat annuloplasty rings. METHODS AND RESULTS: Sixteen 80-kg pigs had a flat (n=8) or saddle-shaped (n=8) mitral annuloplasty ring implanted. Mitral annulus 3D dynamic geometry was obtained with sonomicrometry before ring insertion. Strain gauges mounted on dedicated D-shaped rigid flat and saddle-shaped annuloplasty rings provided the intraoperative force distribution perpendicular to the annular plane. Average systolic annular height to commissural width ratio before ring implantation was 14.0%+/-1.6%. After flat and saddle shaped ring implantation, the annulus was fixed in the diastolic (9.0%+/-1.0%) and systolic (14.3%+/-1.3%) configuration, respectively (P<0.01). Force accumulation was seen from the anterior (0.72N+/-0.14N) and commissural annular segments (average 1.38N+/-0.27N) of the flat rings. In these segments, the difference between the 2 types of rings was statistically significant (P<0.05). The saddle-shaped annuloplasty rings did not experience forces statistically significantly larger than zero in any annular segments. CONCLUSIONS: Saddle-shaped annuloplasty rings provide superior uniform annular force distribution compared to flat rings and appear to represent a configuration that minimizes out-of-plane forces that could potentially be transmitted to leaflets and chords. This may have important implications for annuloplasty ring selections.
No takes yet. Share an insight, caveat, or question.
Jensen et al. (2008) studied Mitral valve annuloplasty (animal model) (n=16). Saddle-shaped annuloplasty rings vs. Flat annuloplasty rings was evaluated on Intraoperative force distribution perpendicular to the annular plane (p=<0.05). Saddle-shaped annuloplasty rings experienced significantly lower out-of-plane forces compared to flat rings, which showed force accumulation in anterior and commissural segments (P<0.05).