The treatment of simulated textile wastewater [chemical oxygen demand (COD) = 3360 mg/L] was performed using three chemical/physicochemical processes, viz., coagulation, Fenton oxidation, and adsorption. Coagulation of the wastewater was performed in a jar test apparatus using inorganic and organic coagulants. The best color removal (∼96%) was obtained with FeSO 4 while FeCl 3 and MgCl 2 caused ∼75% and ∼53% color removal, respectively. The optimum dose for iron-based coagulants was 3 g/L, whereas it was 6 g/L for MgCl 2 . FeSO 4 -treated wastewater showed the best results with regard to the settling of flocs. Chitosan was effective for the decolorization of wastewater at low dose (=10 mg/L) and acidic pH (∼3.0) showing ∼20% and 30% COD and color reductions, respectively. For coagulation with FeSO 4 followed by adsorption, overall COD and color removal of 85% and 99%, respectively, could be achieved. The raw wastewater treated by Fenton’s process (H 2 O 2 dose = 10.5 g/L and H 2 O 2 /Fe 2+ molar ratio = 20) exhibited COD and color removal of ∼80% and 99%, respectively. Using Fenton oxidation as a post-treatment step after coagulation with FeSO 4, the COD removal was enhanced to ∼83%, although the color removal remained unaffected. The sequential treatment also increased the BOD 5 (biochemical oxygen demand) to COD ratio of the treated wastewater to 0.51.
No takes yet. Share an insight, caveat, or question.
Yadav et al. (2013) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: