Standardized tests for portable air cleaners (PACs) typically evaluate devices in small, well-mixed chambers with central placement and no interaction with mechanical ventilation (MV), diverging significantly from real-world operation. This study bridges this gap by systematically evaluating PAC performance under more realistic, yet controlled, conditions in a large test room (202.0 m³) where mixing fans are switched off during measurement, allowing non-ideal mixing conditions to develop, and where MV interaction is explicitly accounted for. Three representative PAC types, horizontal front discharge (Type I), vertical upward discharge (Type II), and horizontal table-mounted discharge (Type III), are evaluated at up to six positions in PAC-only and combined PAC+MV (ACH = 3 h⁻¹) scenarios across four particle size ranges (PM 0.25 , PM 0.25–0.5 , PM 0.5–3 , and PM 3–10 ). Placement sensitivity is strongly particle-size dependent: fine particle CADR pr differences are typically within 15% (S = 5–19%), while coarse particles show variations up to 46% (e.g., the upward-discharge PAC at low fan speed with MV, +887 m³/h relative to central placement). Central placement, commonly recommended in standards, is not universally optimal, consistently underperforming for Type II and showing position-dependent performance for Type I and III. PAC–MV interaction is generally near-additive for both fine and coarse particles; meaningful super- or sub-additive effects are limited to selected coarse-particle cases, where the interaction factor exceeds the uncertainty threshold (±0.16). Spatial spread analysis reveals that high average air cleaning performance can coincide with highly uneven room coverage, highlighting that CADR pr alone is insufficient to assess overall effectiveness.
No takes yet. Share an insight, caveat, or question.
Xia et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: