Key result
Single antiplatelet therapy after drug-coated balloon PCI is associated with similar MACE rates as dual therapy.
Observational (n=1,110)
Absolute Event Rate: 9% vs 10%
p-value: p=0.78
Drug-coated balloons are a complementary technology to drug-eluting stents that allow for abbreviated antithrombotic therapy, particularly useful in high bleeding risk patients and specific lesion types.
Drug choice between paclitaxel- and sirolimus-eluting balloons remains uncertain in PCI; leaves open need for head-to-head trials.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Caballero et al. (2026) conducted an observational in Coronary artery disease requiring percutaneous coronary intervention (n=1,110). Single antiplatelet therapy (SAPT) vs. Dual antiplatelet therapy (DAPT) was evaluated on MACE (Cardiac death, MI, TLR) at 12 months (p=0.78). Single antiplatelet therapy after drug-coated balloon PCI was associated with similar 12-month MACE rates compared to dual antiplate.