Key result
Serial testing of vagally mediated carotid baroreceptor-cardiac reflex responses demonstrated high reproducibility, with linear regression correlation coefficients ranging from 0.64 to 0.99.
Observational (n=34)
Human vagally mediated carotid baroreceptor-cardiac reflex responses are highly reproducible when studied serially under exacting experimental conditions.
Answers are grounded in this paper and cite their sources.
Reproducibility supports serial baroreflex testing in controlled research; leaves open clinical translation beyond exacting conditions.
Published information on the reproducibility of human baroreflex responses in the absence of interventions is limited. Therefore, we analyzed retrospectively vagally mediated carotid baroreceptor-cardiac reflex responses of 34 healthy young adult volunteers whom we studied twice, 7-10 days apart (all 34 subjects) or 10 wk apart (8 subjects). We delivered a sequence of neck pressure changes during held expiration: A computer-driven bellows initially raised pressure to approximately 40 mmHg for five heart beats, and then reduced pressure in a stepwise series of R-wave-triggered 15-mmHg decrements to about -65 mmHg. R-R interval changes were plotted as functions of the carotid distending (systolic less neck) pressure occurring within each interval. Each experimental session yielded one stimulus-response relation, which comprised the average of seven separate trials. Six measures were derived from these relations: minimum, maximum, and range of R-R intervals; maximum slope; and operational point [(R-R interval shortening/R-R interval range) x 100%]. Linear regression correlation coefficients for measurements made on two occasions were all highly significant (range: 0.64-0.99). Our results indicate that human vagally mediated carotid baroreceptor-cardiac reflex responses, studied serially under exacting experimental conditions, are highly reproducible.
No takes yet. Share an insight, caveat, or question.
Eckberg et al. (1992) conducted an observational in Healthy (n=34). Serial testing of carotid baroreceptor-cardiac reflex responses vs. Test-retest (measurements made on two occasions) was evaluated on Reproducibility of R-R interval measures (minimum, maximum, range, maximum slope, operational point) (Correlation coefficients 0.64-0.99, p=highly significant). Serial testing of vagally mediated carotid baroreceptor-cardiac reflex responses demonstrated high reproducibility, with linear regression correlation coefficients ranging from 0.64 to 0.99.
Synapse has enriched 10 related papers. Consider them for comparative context: