Answers are grounded in this paper and cite their sources.
Current design codes reduce the shear strength of individual bolts to account for potentially uneven distribution of force among the bolts including a 0.75/0.90 (83.3%) step function at 38 in. Available test data indicate there is no justification for a bolt shear strength reduction, especially the step function, due to the length of connection, provided that second-order effects are limited and gross and net section areas slightly exceed the AISC Specification limits (2010). A practical, empirical solution is proposed that maintains a reliability, ?, slightly greater than 4.0 for all connection lengths, using the current AISC resistance factor, ?, of 0.75.
No takes yet. Share an insight, caveat, or question.
Raymond H.R. Tide (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: