Key result
Real-time 3-dimensional echocardiography showed moderate correlations with 64-slice multi-detector cardiac computed tomography for measuring biventricular volumes in patients with cor pulmonale.
Why the study?
Does real-time 3-dimensional echocardiography accurately measure biventricular volumes and ejection fractions compared to 64-MDCT in patients with cor pulmonale?
Observational (n=22)
Blinded
No
Does real-time 3-dimensional echocardiography accurately measure biventricular volumes and ejection fractions compared to 64-MDCT in patients with cor pulmonale?
Real-time 3-dimensional echocardiography is a feasible and modest method for measuring distorted biventricular volumes and stroke volumes in patients with cor pulmonale who cannot undergo cardiac magnetic resonance imaging.
Answers are grounded in this paper and cite their sources.
May support 3D echo for biventricular volumes in cor pulmonale when CMR unavailable; leaves open prospective validation studies.
BACKGROUND: This study was to investigate the feasibility of real-time 3-dimensional echocardiography (RT3DE) for the analysis of biventricular ejection fractions and volume measurements in patients with cor pulmonale and the correlations of RT3DE results with 64-slice multi-detector cardiac computed tomography (64-MDCT) results. METHODS: This study included a total of 22 patients (59.3 ± 16.6 years of age; 10 males and 12 females) who showed flattening or reverse curvature of the interventricular septum and severe pulmonary hypertension [mean right ventricular (RV) systolic pressure = 66.8 ± 19.7 mmHg] on 2-dimensional transthoracic echocardiography due to cor pulmonale. Biventricular end-diastolic and end-systolic volumes were measured by RT3DE and 64-MDCT. The severity of D-shaped deformation was evaluated by using left ventricular (LV) eccentricity index (ratio of diameters parallel/perpendicular to the interventricular septum on parasternal short axis images of the papillary muscle level). RESULTS: There were moderate correlations between biventricular volumes measured by RT3DE and 64-MDCT except for LV end-systolic volume (59.8 ± 17.1 vs. 73.2 ± 20.2 mL, r = 0.652, p = 0.001 for LV end-diastolic volume; 30.6 ± 9.1 vs. 30.8 ± 12.5 mL, r = 0.361, p = 0.099 for LV end-systolic volume; 110.1 ± 42.9 vs. 171.1 ± 55.3 mL, r = 0.545, p = 0.009 for RV end-diastolic volume; and 80.9 ± 35.0 vs. 128.7 ± 45.1 mL, r = 0.549, p = 0.005 for RV end-systolic volume respectively). CONCLUSION: This study suggests that RT3DE may be a modest method for measuring distorted biventricular end-systolic and end-diastolic volumes in patients with cor pulmonale.
No takes yet. Share an insight, caveat, or question.
Cho et al. (2013) conducted an observational in Cor pulmonale (n=22). Real-time 3-dimensional echocardiography (RT3DE) vs. 64-slice multi-detector cardiac computed tomography (64-MDCT) was evaluated on Left ventricular end-diastolic volume (r = 0.652, p=0.001). Real-time 3-dimensional echocardiography showed moderate correlations with 64-slice multi-detector cardiac computed tomography for measuring biventricular volumes in patients with cor pulmonale.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: