Key result
Chronic subjective tinnitus was associated with a 34% increase in the occurrence of EEG Microstate A during the closing-eyes state compared to healthy controls.
Why the study?
Chronic tinnitus lacks precise diagnostic or effective therapeutic standards, its mechanisms remain unclear, and objective assessment methods are lacking.
Do EEG microstate parameters differ between chronic tinnitus patients and healthy controls across different resting states?
Cross-Sectional (n=36)
Yes
Do EEG microstate parameters differ between chronic tinnitus patients and healthy controls across different resting states?
Effect estimate: 34% increase
Absolute Event Rate: 3.506% vs 2.613%
p-value: p=<0.05
EEG microstate parameters, particularly Microstate A in the eyes-closed state, show significant alterations in chronic tinnitus patients and may serve as objective neurophysiological markers.
Should not yet change tinnitus assessment; leaves open EEG microstates as biomarkers pending prospective validation.
Chronic tinnitus is highly prevalent but lacks precise diagnostic or effective therapeutic standards. Its onset and treatment mechanisms remain unclear, and there is a shortage of objective assessment methods. We aim to identify abnormal neural activity and reorganization in tinnitus patients and reveal potential neurophysiological markers for objectively evaluating tinnitus. By way of analyzing EEG microstates, comparing metrics under three resting states (OE, CE, and OECEm) between tinnitus sufferers and controls, and correlating them with tinnitus symptoms. This study reflected specific changes in the EEG microstates of tinnitus patients across multiple resting states, as well as inconsistent correlations with tinnitus symptoms. Microstate parameters were significantly different when patients were in OE and CE states. Specifically, the occurrence of Microstate A and the transition probabilities (TP) from other Microstates to A increased significantly, particularly in the CE state (32-37%, p ≤ 0.05 ); and both correlated positively with the tinnitus intensity. Nevertheless, under the OECEm state, increases were mainly observed in the duration, coverage, and occurrence of Microstate B (15-47%, ), which negatively correlated with intensity ( [Formula: see text]-0.513, ). Additionally, TPx between Microstates C and D were significantly reduced and positively correlated with HDAS levels ( [Formula: see text] 0.548, ). Furthermore, parameters of Microstate D also correlated with THI grades ( [Formula: see text]-0.576, ). The findings of this study could offer compelling evidence for central neural reorganization associated with chronic tinnitus. EEG microstate parameters that correlate with tinnitus symptoms could serve as neurophysiological markers, contributing to future research on the objective assessment of tinnitus.
No takes yet. Share an insight, caveat, or question.
Zeng et al. (2024) conducted a cross-sectional in Chronic subjective tinnitus (n=36). Chronic subjective tinnitus vs. Healthy controls was evaluated on Occurrence of EEG Microstate A in the closing-eyes (CE) state (Times/s) (34% increase, p=<0.05). Chronic subjective tinnitus was associated with a 34% increase in the occurrence of EEG Microstate A during the closing-eyes state compared to healthy controls.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: