Answers are grounded in this paper and cite their sources.
Methods for the determination of CS-570, a chemically stable prostacyclin analogue, in plasma were developed by using an immobilized antibody column followed by fluorescence HPLC and GC/MS. The CS-570 antibody, obtained from rabbit plasma by giving CS-570-BSA for a few months, was coupled to Sepharose 4B and used as extraction phase for sample clean-up and extraction of the drug. A plasma sample was applied to this column, washed with water and the drug was eluted with 90% acetonitrile. 0.02% (w/v) 9-anthryldiazomethane (ADAM) was added to the extract to form a fluorescent derivative. The CS-570-ADAM adduct exhibited high sensitivity when applied to HPLC with fluorescence detection and column switching. The detection limit was 1 ng/mL when 1 mL of plasma was available. Additionally, a pentafluorobenzyltrimethylsilyl derivative of CS-570 showed excellent sensitivity when determined by capillary GC interfaced to negative ion chemical ionization MS using a stable isotope labelled analogue as an internal standard.
No takes yet. Share an insight, caveat, or question.
Nakagawa et al. (1987) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: