Key result
Explainable CNN framework achieves ~100% accuracy for ECG arrhythmia classification on the MITDB dataset.
Why the study?
Clinical adoption of deep learning for automated ECG arrhythmia detection is hindered by overfitting, computational demands, and a lack of interpretability.
An explainable deep learning framework combining CNN and random over-sampling achieves >99% accuracy in detecting arrhythmias from benchmark ECG datasets while providing interpretability through XAI.
Warrants prospective clinical validation; leaves open adoption of explainable deep learning for arrhythmia detection.
Cardiovascular diseases (CVDs) constitute a foremost global health challenge, with cardiac arrhythmias significantly increasing both mortality and morbidity. Early and precise detection of these arrhythmias from Electrocardiogram (ECG) signals is paramount but inherently complex due to the vast volume, diverse characteristics and variability of ECG data. While Deep Learning (DL) models offer transformative potential for automated ECG analysis, their widespread clinical adoption is hindered by issues such as susceptibility to overfitting, high computational demands and a notable lack of interpretability, resulting in black-box systems. This paper presents an explainable DL framework for accurate and reliable arrhythmia detection. Our innovative approach integrates advanced DL architectures, specifically Convolutional Neural Network (CNN) and Dense Neural Network (DNN), within a sophisticated multi-stage pipeline. This pipeline encompasses meticulous data preparation, state-of-the-art signal preprocessing and robust multi-strategy data balancing techniques, including ADASYN, SMOTE, SMOTETomek and Random Over-Sampling (ROS), to maximize model performance and generalization. Crucially, the framework incorporates Explainable Artificial Intelligence (XAI) methodologies-namely SHAP, LIME and Feature Importance Analysis (FIA) to provide transparent insights into the model's decision-making process. Rigorous evaluation on benchmark ECG datasets such as MITDB, PTBDB and NSTDB, demonstrates superior classification accuracy, with our ROS+CNN model achieving 99.74%, 99.43% and 99.98%, respectively. The embedded XAI components offer actionable interpretability, fostering clinical trust and paving the way for more reliable and impactful AI-driven cardiovascular diagnostics.
No takes yet. Share an insight, caveat, or question.
Talukder et al. (2025) studied Cardiac arrhythmias. Explainable Deep Learning Framework (ROS+CNN) vs. Other data balancing techniques (ADASYN, SMOTE, SMOTETomek) and DNN was evaluated on Classification accuracy on MITDB dataset. The proposed explainable deep learning framework using Random Over-Sampling and a Convolutional Neural Network achieved 99.74% classification accuracy for arrhythmia detection on the MITDB dataset.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: