Key result
Invasive Rμ,hyper from continuous thermodilution strongly correlates with PET but not with IMR.
Why the study?
It was unknown how invasive continuous thermodilution-derived hyperemic microvascular resistance compares to gold-standard [15O]H2O PET and correlates with bolus thermodilution-derived IMR.
Does continuous thermodilution (invasive Rμ,hyper) correlate with [15O]H2O PET Rμ,hyper and bolus thermodilution (IMR) in assessing microvascular resistance?
Observational (n=274)
Does continuous thermodilution (invasive Rμ,hyper) correlate with [15O]H2O PET Rμ,hyper and bolus thermodilution (IMR) in assessing microvascular resistance?
Continuous thermodilution accurately measures absolute microvascular resistance compared to the PET gold standard, whereas bolus thermodilution (IMR) does not correlate with absolute resistance in patients with angina and non-obstructive coronary arteries.
Continuous thermodilution may better reflect absolute microvascular resistance than IMR; leaves open its clinical utility in angina with non-obstructive coronaries.
Background Continuous thermodilution quantifies absolute microvascular resistance (R μ , Wood units), a key metric of microvascular function. R μ is minimal during hyperemia (R μ,hyper ) with increased R μ,hyper suggestive of microvascular dysfunction. Bolus thermodilution measures the index of microcirculatory resistance (IMR), a dimensionless surrogate of R μ,hyper . Aims We compared R μ,hyper measured by continuous thermodilution (invasive R μ,hyper ) with the gold standard [ 15 O]H 2 O positron emission tomography (PET R μ,hyper ), and assessed the correlation between invasive R μ ,hyper and IMR. Methods First, the accuracy of invasive R μ,hyper was assessed in a cohort of 24 patients in which both invasive R μ,hyper and PET R μ,hyper were measured in the left anterior descending (LAD) and circumflex (LCX) arteries, corresponding to 46 measurements of R μ,hyper in total (LAD = 24, LCX = 22). Next, agreement between invasive R μ,hyper and IMR was evaluated in the LAD in a cohort of 250 patients with angina and non‐obstructive coronary arteries. Results Invasive R μ,hyper exhibited a strong correlation with PET R μ,hyper (r = 0.86 [95% CI 0.76–0.92], p < 0.001), with good absolute agreement (ICC 0.82 [95% CI 0.70–0.90], p < 0.001). Passing‐Bablok regression analysis found no significant systematic (intercept A: 54.53 [95% CI ‐18.95 to 120.96]) or proportional (slope B: 0.90 [95% CI 0.71–1.15]) bias between invasive R μ,hyper and PET R μ,hyper . However, invasive R μ,hyper exhibited no significant correlation with IMR (r = 0.11 [95% CI ‐0.01 to 0.23], p = 0.08). Conclusion Invasive R μ,hyper derived from continuous thermodilution exhibited excellent agreement with noninvasive R μ,hyper measured by [ 15 O]H 2 O PET, the current non‐invasive standard of reference. In contrast, IMR exhibited no significant correlation with invasive R μ,hyper in patients with angina and non‐obstructive coronary arteries.
No takes yet. Share an insight, caveat, or question.
Mahendiran et al. (2025) conducted an observational in Angina and non-obstructive coronary arteries (n=274). Continuous thermodilution (invasive Rμ,hyper) vs. [15O]H2O PET and bolus thermodilution (IMR) was evaluated on Correlation between invasive Rμ,hyper and PET Rμ,hyper (r = 0.86, 95% CI 0.76-0.92, p=<0.001). Invasive Rμ,hyper derived from continuous thermodilution exhibited strong correlation with PET Rμ,hyper (r=0.86, 95% CI 0.76-0.92, p<0.001), but no significant correlation with IMR (r=0.11, p=0.08).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: