Answers are grounded in this paper and cite their sources.
Non-invasive range measurement of particle beams is important to prevent deviation of the irradiated area in particle therapy. In this study, we made an experiment of imaging carbon-ion beams by setting the projection ranges into an acrylic target from 4.29 cm to 7.65 cm by a pitch of 0.21 cm. Secondary electron bremsstrahlung (SEB) generated on the beam trajectories were detected for the imaging by use of a pinhole camera system consisting of a pinhole collimator and a position-sensitive cadmium-telluride semiconductor detector (CdTe imager). Beam images were acquired, and their profiles along the longitudinal axis were numerically analyzed, to obtain a suitable parameter that was strongly correlated with the set range. Then we could propose a scheme to measure the particle beam range in the target during irradiation by use of the CdTe imager. As a result, the range shift can be measured in the case of the acrylic target with an accuracy of 0.1 cm.
No takes yet. Share an insight, caveat, or question.
Tsuda et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: