PTFE graft interposition successfully corrects internal carotid kinking and restenosis without postoperative complications.
Case Report (n=1)
No
Graft interposition may be a viable surgical approach for patients with concomitant carotid restenosis and kinking of the internal carotid artery after previous endarterectomy.
Answers are grounded in this paper and cite their sources.
Graft interposition may address post-CEA restenosis with kinking; hypothesis-generating and leaves open safety in larger cohorts.
According to the literature data, the prevalence of restenosis after carotid endarterectomy ranges between 6 and 36%. The etiological factor is intimal hyperplasia for early period, whereas it is atherosclerosis for late period. A 67-year-old male patient admitted to our clinic with a history of headache and minor stroke. His medical history was significant for right carotid endarterectomy 8 years ago. Recent Doppler ultrasound and digital substraction angiography revealed 75% stenosis and kinking corresponding to the segment distal to the endarterectomy region. Surgical endarterectomy is the treatment of choice in critical carotid stenosis. Endovascular therapy is primarily considered for patients if there is restenosis after carotid endarterectomy. However, the treatment modality is controversial in cases with concomitant carotid stenosis and kinking of internal carotid artery. We present our surgical approach to a case with significant stenosis and kinking of internal carotid artery. We performed a 6-mm-PTFE graft interposition between common and internal carotid artery and resection of the kinking segment.
No takes yet. Share an insight, caveat, or question.
Yaşa et al. (2011) conducted a case report in Carotid artery restenosis (75%) and kinking following prior carotid endarterectomy (n=1). 6-mm-ringed PTFE graft interposition between common and internal carotid artery with resection of kinked segment was evaluated on Surgical resolution of kinking and postoperative complication-free discharge. Synthetic 6-mm PTFE graft interposition shortened the internal carotid artery by 2.4 cm to correct kinking and 75% restenosis, allowing complication-free discharge on postoperative day 5.
Synapse has enriched 10 related papers. Consider them for comparative context: