Key result
Intracardiac echocardiography and transesophageal echocardiography demonstrate comparable success and complication rates for guiding transcatheter atrial septal defect closure.
Why the study?
Does intracardiac echocardiography (ICE) guidance improve procedural outcomes or reduce complications compared to transesophageal echocardiography (TEE) in patients undergoing transcatheter closure of atrial septal defects?
Does intracardiac echocardiography (ICE) guidance improve procedural outcomes or reduce complications compared to transesophageal echocardiography (TEE) in patients undergoing transcatheter closure of atrial septal defects?
Answers are grounded in this paper and cite their sources.
ICE provides a safe and effective alternative to TEE for guiding transcatheter ASD closure, with comparable success rates and potential benefits in procedure time and anesthesia requirements, though TEE remains valuable for complex cases.
ICE) was first used experimentally in 1991 to visualize ASD closure devices. Since the early 2000s, ICE, together with TEE, has played an important role in the morphologic evaluation of defects, guidance of the and procedure-related complications. To date, several studies have compared the advantages and disadvantages of ICE and TEE guidance for transcatheter ASD closure (Table ). The greatest advantage of ICE is that it does not require general anesthesia, which has been shown to reduce both procedure time and hospital stay. 5-9 In addition, almost all previous studies have reported that ICE-and TEE-guided ASD closure achieved comparable success and complication rates. 6-9 Against this background, the use of ICE as guidance for ASD closure in the USA increased dramatically from approximately 10% to 50% between 2003 and 2014. 7 A trial septal defect (ASD) accounts for 7-13% of cases of congenital heart disease (CHD) and is one of the most common CHD found in adults. Today, approximately 1,200 procedures are performed annually in Japan using 3 currently available devices: the Amplatzer Septal Occluder device (Abbott, Chicago, IL, USA), Occlutech Figulla Flex II device (Occlutech GmbH, Jena, Germany), and Gore Cardioform ASD Occluder (Japan Gore, Tokyo, Japan). 1 In the early days of transcatheter ASD closure, transesophageal echocardiography (TEE) was primarily used as the imaging mode during procedures. The prototype of intracardiac echocardiography
No takes yet. Share an insight, caveat, or question.
Machino‐Ohtsuka et al. (2023) conducted an editorial in Atrial septal defect. Intracardiac echocardiography (ICE) vs. Transesophageal echocardiography (TEE) was evaluated. Intracardiac echocardiography and transesophageal echocardiography demonstrate comparable success and complication rates for guiding transcatheter atrial septal defect closure.
Synapse has enriched 10 related papers. Consider them for comparative context: