Key result
An incremental cadence protocol was equally effective as an incremental resistance protocol in eliciting peak O2 (3.9 vs. 4.0 L/min) in trained recreational cyclists.
Why the study?
Does an incremental cadence protocol elicit similar O2max compared to an incremental resistance protocol in trained cyclists?
RCT (n=10)
Randomized order
Does an incremental cadence protocol elicit similar O2max compared to an incremental resistance protocol in trained cyclists?
Absolute Event Rate: 3.9% vs 4%
An incremental cadence protocol is as reliable and valid as a traditional incremental resistance protocol for eliciting O2max in trained cyclists.
Supports cadence-based VO2max testing as a valid alternative in trained cyclists; confirms equivalence to resistance protocols in an RCT.
Cycle tests for maximal oxygen uptake (O2max) have traditionally used incremental resistance protocols (RP) at a constant cadence. The purpose of this study was to evaluate whether an incremental cadence protocol (CP) using a constant resistance relative to gross body mass was as reliable and valid in eliciting O2max as RP in trained cyclists. Ten male recreational cyclists aged 25.2 ± 6.8 years completed two CP and one RP trials in a randomized order over a 3-week period. The CP started at a workload of 2.75 W per kg body mass, with the cadence increased by 10 rpm each minute from 70 rpm. The RP started from 125 W with workload increased 25W each minute with a constant cadence of 90 rpm. The results showed no significant differences between the CP (mean of the two CP trials) and RP for peak O2 (3.9 ± 0.6 vs. 4.0 ± 0.8 L·min−1), peak ventilation (140.5 ± 22.8 vs. 143.0 ± 27.1 L·min−1) and post-exercise blood lactate (11.4 ± 2.1 vs. 11.9 ± 1.6 mmol·L−1), while peak heart rate (183.9 ± 10.5 vs. 187.5 ± 11.4 beats·min−1) and peak workload (319.9 ± 60.2 vs. 375.1 ± 67.3W) were significantly less for the CP than the RP. For the two CP trials, the intraclass correlation coefficient for test-retest reliability was 0.96, the technical error of measurement (TEM) was 0.17 L·min−1, and the relative TEM was 4.35%. The results indicate that the CP is equally effective in eliciting O2max as the RP and is a reliable method of measuring O2max in trained recreational cyclists.
No takes yet. Share an insight, caveat, or question.
Deakin et al. (2011) conducted an RCT in Trained recreational cyclists (n=10). Incremental cadence protocol (CP) vs. Incremental resistance protocol (RP) was evaluated on Peak O2. An incremental cadence protocol was equally effective as an incremental resistance protocol in eliciting peak O2 (3.9 vs. 4.0 L/min) in trained recreational cyclists.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: