Answers are grounded in this paper and cite their sources.
EDITOR: The ProSeal® laryngeal mask airway™ (PLMA) (Intavent Orthofix, Maidenhead, UK) is designed to maintain the airway and allow controlled ventilation of the lungs while separating the digestive and respiratory tracts [1]. It provides a better laryngeal seal than the classic laryngeal mask airway (LMA) [2] and allows reliable placement of a gastric tube [2]. It has been suggested as having a role in providing airway management in patients with reduced chest compliance [2]. A 47-yr-old former boxer presented for elective repair of a large paraumbilical hernia and excision of anal skin tags. His only medical history was of asthma, for which he took Symbicort® (AstraZeneca UK Ltd, Luton, UK) (fluticasone and efemoterol) and salbutamol inhalers. He had one previous hospital admission with asthma and had no nocturnal symptoms. He weighed 120 kg at 1.66 m in height (body mass index (BMI) 43.5 kg m−2). He had had one previous general anaesthetic when conventional tracheal intubation had been impossible. He had been awoken from anaesthesia and tracheal intubation achieved with awake fibreoptic intubation. No further details were available. He did not report a history of reflux or indigestion. The patient was fasted for 10 h before surgery. On examination he was obese with a thick short neck with a good range of movement and mouth opening (Mallampati Class I). His chest was clear. The case was discussed with the surgeon who confirmed that muscular relaxation would be preferable for ease of surgery. He was premedicated with diclofenac 75 mg orally. After pre-oxygenation for 5 min he was anaesthetized with fentanyl (100 μg) and a moderate dose of propofol (100 mg). Spontaneous respiration was maintained and anaesthesia was deepened with sevoflurane 4% and nitrous oxide 56% in oxygen 40%. After deepening anaesthesia, a size 5 Guedel airway was inserted. The ability to assist ventilation was confirmed and a size 5 PLMA was placed on the first attempt using an introducer. Laryngeal seal pressure was tested and found to be above 40 cmH2O with no leak detected either to the stomach or via the mouth. The lungs were ventilated with a tidal volume of 6 mL kg−1 at a rate of 12 breaths min−1 and an I : E ratio of 1 : 2. Peak airway pressure was 30 cmH2O. Capnography was square waved. A 14-G gastric tube was placed via the PLMA drain tube on the first attempt and a volume of 120 mL of gastric fluid was withdrawn. Sodium citrate 0.3 mol 30 mL was injected into the gastric tube. Anaesthesia was maintained with sevoflurane (end-tidal concentration 2%) and nitrous oxide 58% in oxygen 40% with rocuronium for muscular relaxation. Fresh gas flow was 700 mL kg−1 via a circle system. End-tidal carbon dioxide was maintained between 4.5 and 6.0 mmHg. Oxygen saturation remained above 96% throughout anaesthesia. Surgery was uneventful. During excision of anal skin tags, the patient was placed in lithotomy position with a 10° head-down tilt during which peak airway pressure rose to 40 cmH2O. Gel placed over the PLMA drain tube was not dislodged, and spirometry showed a gas leak of less than 20 mL per breath. At the end of surgery, the gastric tube was re-inserted and a further 30 mL of fluid was withdrawn. Neuromuscular blockade was reversed and spontaneous ventilation re-established. The PLMA was removed without cuff deflation after return of consciousness 5 min later. There were no airway complications. Emergence and recovery were smooth and uncomplicated and the patient was discharged from hospital the following day. This patient presented a potentially difficult airway problem because of his size, previous history of failed conventional intubation and the need for surgery of the upper abdomen. The risk of difficulty in establishing and maintaining his airway was considered to be greater then the risk of regurgitation, for which the only risk factor was his size. Regional anaesthesia would have been technically difficult because of the patient's obesity. A relatively high block would have been required with potential respiratory and cardiovascular complications. The hernia was considered too large for treatment under local anaesthesia alone, and the patient also needed anal surgery. The patient himself was keen to avoid regional anaesthesia and therefore general anaesthesia was agreed with the patient aware of the potential risks. The alternatives to use of the PLMA were the use of an alternative LMA or fibreoptic intubation. A classic LMA provides a seal at airway pressures exceeding 30 cmH2O in only approximately 4% of patients and rarely, if ever, above 40 cmH2O [2]. Gas leakage into the oesophagus during controlled ventilation with the classic LMA increases with increasing airway pressure and exceeds 30% at an airway pressure of 30 cmH2O [3]. It is exceedingly unlikely that a classic LMA would have been effective in this case and both ineffective ventilation and gastric distension might have occurred. The intubating LMA would have been an appropriate alternative to assist tracheal intubation, but if this failed would suffer from problems similar to those of the classic LMA [4]. Conventional intubation might have been successful, but had failed on a previous occasion. Fibreoptic intubation would have been an entirely acceptable alternative but the patient wished to be asleep. Fibreoptic intubation was ‘plan B’ if use of the PLMA had failed. The PLMA provided an effective solution to this airway management problem. Elective use of the PLMA in the circumstances of a known difficult airway has been reported in a very limited number of cases [5,6]. The distinct advantages of the PLMA in this case were the ability to (1) maintain the airway without recourse to tracheal intubation, which had failed in the past; (2) provide positive-pressure ventilation in a patient with poor lung/chest wall compliance; (3) effectively drain the stomach in a patient in whom, despite the absence of symptoms, this might be considered desirable. This technique might be criticized in a number of details. Some would apply cricoid pressure after loss of consciousness. Cricoid pressure interferes with placement of the laryngeal mask. Cricoid pressure also decreases lower oesophageal sphincter pressure [7]. Secondly, laryngoscopy was not performed to determine whether or not conventional intubation was possible. Laryngoscopy is in itself a risk factor for regurgitation and 35% of cases of aspiration during anaesthesia occur during laryngoscopy. I wished to minimize both airway stimulation and the time between induction of anaesthesia and establishing an airway. Laryngoscopy at the end of surgery would have required removal of the PLMA and this was not considered justified. While the technique used was clearly not the only possible technique, it provided optimal anaesthetic and surgical conditions while allowing effective drainage of the stomach. Conflict of interest The author, TM Cook, has received a small honorarium for addressing a sales meeting of the company Intavent Orthofix. T. M.
No takes yet. Share an insight, caveat, or question.
Tim Cook (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: