Key result
In an experimental model of intra-arterial circulation, simulated premature ventricular contractions and atrial fibrillation increased intravascular pressure by up to 58% and 44%, respectively, compared to regular rhythm.
Why the study?
The study was conducted to examine the features of intravascular hemodynamics with a regular heart rhythm and various rhythm disturbances using an original device modeling intra-arterial blood circulation.
An experimental in vitro model demonstrates significant pressure increases during post-extrasystolic beats and long pauses in atrial fibrillation.
Purpose of study Using an original device for modeling of intra-arterial blood circulation, to study the features of intravascular hemodynamics with a regular heart rhythm and with various rhythm disturbances. Material and methods We used an original device developed by us to simulate intra-arterial circulation (Document of invention No. RU 202780 U1). The main part of the device is a glass tube of a rotameter with a length of 365 mm, an inlet end with a diameter of 20 mm, an outlet end of 16.5 mm, which is a model of an arterial vessel. Flexible silicone tubes are attached to the rotameter on both sides, with free ends connected to an electric pump, with various modes of operation (imitation of pulse waves with regular rhythm, premature ventricular contractions (PVCs), atrial fibrillation (AF). An aqueous solution of glycerin was introduced into a closed system diluted with water corresponding to the viscosity of the blood. A 5 mm long silk thread was alternately installed inside the tube, an intravascular piezoelectric crystal pressure probe connected to an oscilloscope. Also it was injected inside the tube a dye - clerical ink. Results With electric pump, we simulated the spreading of the pulse wave in regular heart rate, PVCs and AF. We observed the effect of a pressure wave (deflection of a silk thread, the appearance of a turbulent flow when using a dye) on the walls of the rotameter, with the formation of standing, reflected waves during the PVCs and AF. The pressure probe registered an increase in pressure inside the tube during the spread of the 1st post-extrasystolic contraction wave up to 58%, the wave after a long pause of more than 2 seconds with AF by 44% compared to the regular rhythm. Conclusion A device for modeling of intra-arterial circulation allows a wide range of experimental work in cardiology, normal and pathological physiology, and biophysics.
No takes yet. Share an insight, caveat, or question.
Germanova et al. (2021) studied Intra-arterial circulation modeling. Simulated premature ventricular contractions and atrial fibrillation vs. Regular heart rhythm was evaluated on Increase in pressure inside the tube. In an experimental model of intra-arterial circulation, simulated premature ventricular contractions and atrial fibrillation increased intravascular pressure by up to 58% and 44%, respectively, compared to regular rhythm.