Key result
In stable chronic heart failure patients with an ICD, the early summed score from SPECT 123I-mIBG scintigraphy was an independent predictor of arrhythmic events (HR 1.023).
Why the study?
Does 123I-mIBG scintigraphy predict arrhythmic events in stable chronic heart failure patients referred for ICD implantation?
Observational (n=170)
No
Does 123I-mIBG scintigraphy predict arrhythmic events in stable chronic heart failure patients referred for ICD implantation?
Hazard Ratio: 1.023 (95% CI 1.003–1.043)
p-value: p=0.023
In stable chronic heart failure patients with an ICD, the early summed score from 123I-mIBG SPECT imaging independently predicts arrhythmic events, though there is a non-linear 'bell-shaped' relationship between tracer uptake and event risk.
Should not yet change ICD decisions in stable HF; hypothesis-generating for 123I-mIBG SPECT in arrhythmic risk stratification.
Despite therapeutic improvement, the prognosis of chronic heart failure (CHF) remains unfavorable partly due to arrhythmia and sudden cardiac death (SCD). This prospective study evaluated myocardial 123 I- meta -iodobenzylguanidine ( 123 I- m IBG) scintigraphy as a predictor of arrhythmic events (AE) in CHF patients. 170 CHF patients referred for implantable cardioverter-defibrillator (ICD) implantation for both primary and secondary prevention were enrolled. All patients underwent planar and SPECT imaging. Early and late heart-to-mediastinum (H/M) ratio, 123 I- m IBG washout (WO), early and late summed SPECT scores were calculated The primary endpoint was an AE: sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate ICD therapy or SCD. The secondary endpoint was appropriate ICD therapy. During a median follow-up of 23.3 months, 69 patients experienced an AE. Early summed score (ESS) was the only independent predictor of AE [HR 1.023 (1.003-1.043)]. Focussing on only patients with an ICD for primary prevention, ESS was the only independent predictor of AE [HR 1.028 (1.007-1.050)]. 123 I- m IBG-derived parameters failed to be independent predictors of appropriate ICD therapy. However there was a “bell-shaped” relation between 123 I- m IBG scintigraphy-derived parameters and AE and appropriate ICD therapy, i.e., those with intermediate 123 I- m IBG abnormalities tended to be at higher risk of events. Although SPECT 123 I- m IBG scintigraphy was associated with AE in CHF patients with ICD implantation for primary and secondary prevention, no association was found between 123 I- m IBG scintigraphy-derived parameters and appropriate ICD therapy.
No takes yet. Share an insight, caveat, or question.
Vincentis et al. (2018) conducted an observational in Chronic heart failure (n=170). SPECT 123I-mIBG scintigraphy (Early Summed Score) was evaluated on Arrhythmic events (sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate ICD therapy, or sudden cardiac death) (HR 1.023, 95% CI 1.003-1.043, p=0.023). In stable chronic heart failure patients with an ICD, the early summed score from SPECT 123I-mIBG scintigraphy was an independent predictor of arrhythmic events (HR 1.023).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: