This paper presents the design and analysis of a novel permanent-magnet (PM)-assisted synchronous reluctance machine (PMA-SynRM) with axially integrated magnets for improving machine performance by using a finite-element method (FEM). The proposed PMA-SynRM features a simple structure with high performance by incorporating the advantages of a SynRM and a surface-mounted PM machine (SPMM). In particular, the rotor parts of the SynRM and SPMM are assembled to make the “q-axis” located 45° (elec.) from the d-axis. Thus, the magnetic torque and reluctance torque of the proposed PMA-SynRM reach the maximum values at the same current phase angle, for efficient production of the total torque. To highlight the advantages of the proposed PMA-SynRM, a conventional PMA-SynRM is adopted for comparison under the same operating conditions. The FEM analysis results finally demonstrate that the proposed PMA-SynRM has a higher total torque and power factor, as well as greatly reduced torque ripple, when compared to the conventional PMA-SynRM with the same magnet amounts. In addition, the Mises stress analysis indicates that the configuration of the proposed PMA-SynRM exhibits the advantage of avoiding stress deterioration in the rotor ribs.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2017) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: