Key result
Preoperative administration of esmolol significantly reduced serum troponin I levels at 120 minutes after aortic cross-clamp release compared to control (0.072 vs 0.188 ng/ml, p<0.001) in patients undergoing on-pump cardiac surgery.
Why the study?
Does preoperative intravenous esmolol reduce myocardial injury in patients undergoing elective on-pump cardiac surgery?
RCT (n=24)
Open-label
Computer-generated randomization list
No
Does preoperative intravenous esmolol reduce myocardial injury in patients undergoing elective on-pump cardiac surgery?
Absolute Event Rate: 0.072% vs 0.188%
p-value: p=<0.001
Preoperative intravenous esmolol significantly reduced perioperative troponin I release without causing hemodynamic instability in patients undergoing elective on-pump cardiac surgery.
Supports preoperative esmolol to limit myocardial injury in on-pump cardiac surgery; extends RCT evidence for perioperative beta-blocker cardioprotection.
The protective effects of preprocedural esmolol on myocardial injury and hemodynamics have not, to date, been investigated in patients who were scheduled for cardiac surgeries under a cardiopulmonary bypass (CPB). A pilot randomized controlled trial was performed at The First Affiliated Hospital of Dalian Medical University (Dalian, China). Patients scheduled for elective open-heart surgeries under CBP were included, and were randomized to esmolol and control groups. For patients in the esmolol groups, intravenous esmolol (70 µg/kg/min) was administered at the time of incision until CPB was performed. For patients assigned to the control group, equal volumes of 0.9% saline were administered. Markers of myocardial injury and hemodynamic parameters were observed until 12 h post surgery. A total of 24 patients were included in the present study. No significant differences in hemodynamic parameters, including the central venous pressure and heart rate, were detected between patients in the two groups during the perioperative period or within the first 12 h post-surgery (P>0.05), except for the mean arterial pressure, which was higher in the esmolol group compared with the control group at 5 and 12 h post-surgery (P<0.05). However, the serum level of cardiac troponin I was higher in patients of the control group compared with those of the esmolol group during the preoperative period (P<0.05). Although creatinine kinase was significantly different at T2 between the two groups, its MB isoenzyme was not significantly different between the groups (P>0.05). In addition, administration of esmolol was not associated with an increased risk for severe complications and adverse events in these patients. In conclusion, preoperative esmolol may be an effective and safe measure of myocardial protection for patients who undergo elective cardiac surgeries under CBP.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2016) conducted an RCT in Elective open-heart surgery under cardiopulmonary bypass (n=24). Esmolol vs. 0.9% saline was evaluated on Serum troponin I (TnI) level at 120 minutes after release of aortic cross-clamp (p=<0.001). Preoperative administration of esmolol significantly reduced serum troponin I levels at 120 minutes after aortic cross-clamp release compared to control (0.072 vs 0.188 ng/ml, p<0.001) in patients undergoing on-pump cardiac surgery.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: