Answers are grounded in this paper and cite their sources.
A closed-loop servo-controlled hydraulic testing machine can be used to generate experimentally the complete stress–strain curves for concrete in compression. However, the deformation readings obtained from the built-in low-voltage displacement transducers or other transducers placed between the machine platens include not only deformations of the concrete but also those due to machine flexibility and end-restraint of the specimen. In this paper, a correction factor is proposed to account for these effects. This requires the use of a compressometer fixed directly to the test specimen and transducers placed between the machine platens. More realistic stress–strain curves for concrete with cylinder (100 × 200mm) compressive strengths of up to 130 MPa have thus been obtained for the entire loading range.
No takes yet. Share an insight, caveat, or question.
Mansur et al. (1995) studied this question.