This study determined the variation of current, temperature, pH, and amount of precipitate generated during an electrocoagulation process conducted using a pure iron electrode in 0.1 Na2SO4. Then, the points of zero charge of the hydroxide/oxyhydroxide precipitates thus produced were obtained by two different methods: a simplified mass potentiometic titration method and a salt titration method. The results from both methods yieldedpzc values of 3.6 ± 0.7. This signals the predominance of positively- charged surface groups. Users desiring the removal of specifically-charged water pollutants can use this information to adjust the pH values for such purposes.
No takes yet. Share an insight, caveat, or question.
Cardenas-Peña et al. (2012) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: