Key result
A 1-unit increase in the PADIT score was associated with a 28% relative increase in CIED infection risk, and prior CIED infection provided incremental predictive value.
Why the study?
The PADIT infection risk score identified five independent predictors of CIED infection, but required independent validation in an external dataset.
Observational (n=51,623)
Yes
The PADIT risk score, especially when combined with history of prior CIED infection, effectively predicts the risk of major CIED infections in a real-world claims database.
Answers are grounded in this paper and cite their sources.
Supports PADIT-based CIED infection risk stratification in real-world data; leaves open prospective validation before guiding interventions.
AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.
No takes yet. Share an insight, caveat, or question.
Ahmed et al. (2021) conducted an observational in Cardiac implantable electronic device (CIED) infection (n=51,623). PADIT infection risk score and prior CIED infection vs. Lower PADIT score / no prior CIED infection was evaluated on Major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) (HR 5.66, p=< 0.0001). A 1-unit increase in the PADIT score was associated with a 28% relative increase in CIED infection risk, and prior CIED infection provided incremental predictive value.
Synapse has enriched 10 related papers. Consider them for comparative context: