Key result
Technetium-99m macroaggregated albumin arterial perfusion detected abnormally positioned arterial catheters in 3.4% (17 of 500) of intra-arterial chemotherapy courses.
Why the study?
Does Technetium-99m MAA arteriography improve the detection of abnormally positioned arterial catheters during infusion chemotherapy?
Observational (n=500)
Does Technetium-99m MAA arteriography improve the detection of abnormally positioned arterial catheters during infusion chemotherapy?
Answers are grounded in this paper and cite their sources.
Technetium-99m MAA arterial perfusion is an effective method for detecting abnormally positioned arterial catheters during infusion chemotherapy, outperforming plain radiographs in a small subset.
The arterial catheter position of 500 courses of intra-arterial chemotherapy were monitored by intraarterially introduced Technetium-99m macroaggregated albumin (MAA) particles. Seventeen instances of abnormally positioned catheters (3.4%) were detected by MAA arterial perfusion (MAAAP). All these abnormally positioned catheters were subsequently repositioned resulting in improved tumor perfusion. Plain radiographs obtained in eight instances failed to reveal the abnormally positioned catheter in four, while all eight of these abnormally positioned catheters were detected by MAAAP. Abnormally positioned catheters detected by MAAAP were either immediately after arterial catheter placement (nine instances) or during the course of chemotherapy (eight instances). Of the right instances of displaced catheters during intra-arterial chemotherapy, six instances were accompanied by clinical signs and symptoms suggestive of displaced catheter. Arteriovenous shunting was documented in 5 of 12 hepatic MAAAP studies as evidenced by increased lung activity. When the catheters were displaced in these cases, the lung activity changed: completely disappearing in two instances; decreasing in two instances and remaining unchanged in one.
No takes yet. Share an insight, caveat, or question.
Bledin et al. (1984) conducted an observational in Intra-arterial chemotherapy (n=500). Technetium-99m macroaggregated albumin arterial perfusion (MAAAP) was evaluated on Detection of abnormally positioned arterial catheters. Technetium-99m macroaggregated albumin arterial perfusion detected abnormally positioned arterial catheters in 3.4% (17 of 500) of intra-arterial chemotherapy courses.
Synapse has enriched 10 related papers. Consider them for comparative context: