Answers are grounded in this paper and cite their sources.
It is shown that the procedure of evaluating pressure losses in internally-heated piston-cylinder devices by assuming symmetrical friction is in error below ∼500°C. Previous results may be in error by as much as ∼5 kilobars at 40 kilobars and 25°C. A method of calibration is described which evaluates such unsymmetrical pressure losses.
No takes yet. Share an insight, caveat, or question.
Pistorius et al. (1967) studied this question.