Key result
Elevated serum soluble ST2 levels independently predicted a left atrial low-voltage zone >20% in patients with paroxysmal atrial fibrillation (OR 1.611).
Why the study?
Paroxysmal AF recurrence after RFCA is linked to low-voltage zones, but whether serum soluble ST2 levels can predict LVZ size was unknown.
Does serum soluble ST2 level predict left atrial low-voltage zone size and atrial arrhythmia recurrence in patients with paroxysmal atrial fibrillation undergoing RFCA?
Observational (n=177)
Single-blind
No
Does serum soluble ST2 level predict left atrial low-voltage zone size and atrial arrhythmia recurrence in patients with paroxysmal atrial fibrillation undergoing RFCA?
Odds Ratio: 1.611 (95% CI 1.379–1.882)
p-value: p=<0.001
Elevated serum soluble ST2 levels can serve as a novel biomarker to predict left atrial low-voltage zone size and atrial fibrillation recurrence following radiofrequency catheter ablation.
BACKGROUND Paroxysmal atrial fibrillation (pAF) recurrence after radiofrequency catheter ablation (RFCA) is linked to low-voltage zone (LVZ). This study explored whether serum soluble ST2 (sST2) levels can predict the size of LVZs in patients with pAF. MATERIAL AND METHODS A total of 177 patients with pAF treated with RFCA were consecutively enrolled in this study. One hundred twenty-five patients (70.6%) with <20% LVZ were assigned to Group A, and 52 patients (29.4%) with a LVZ >20% were assigned to Group B. Levels of soluble ST2 (sST2), growth and differentiation factor (GDF-15) and tissue inhibitor of MMP1 (TIMP-1) were measured. RESULTS The sST2 levels were higher in Group B than in Group A (23.9±3.3 vs. 30.9±5.0 ng/mL, P<0.000). In multivariable logistic regression analysis, sST2 was the only independent parameter for predicting left atrial LVZ (odds ratio, 1.611 [1.379-1.882]; P<0.001). The cut-off value of sST2 obtained by receiver operating characteristic (ROC) analysis was 26.65 ng/mL for prediction of LVZ (sensitivity: 86.5%, specificity: 84.8%). The under-curve area was 0.895 (0.842-0.948) (P<0.001). At 12-month follow-up, patients with sST2 <26.65 ng/mL had more patients free from atrial arrhythmias compared to patients with sST2 >26.65 ng/mL (88.6% vs. 69.8%, P<0.01). CONCLUSIONS We demonstrated that sST2 levels are higher in pAF patients with LVZ >20% compared to those with a smaller LVZ. Also increased sST2 levels can serve as a novel predictor of AF recurrence rate in patients who have undergone RFCA.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2020) conducted an observational in Paroxysmal Atrial Fibrillation (n=177). Serum soluble ST2 (sST2) vs. Lower sST2 levels was evaluated on Prediction of left atrial low-voltage zone (LVZ) >20% (OR 1.611, 95% CI 1.379-1.882, p=<0.001). Elevated serum soluble ST2 levels independently predicted a left atrial low-voltage zone >20% in patients with paroxysmal atrial fibrillation (OR 1.611).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: