Key result
Cryoballoon ablation guided by the Navik 3D mapping system achieved acute pulmonary vein isolation in 98% of patients with atrial fibrillation.
Why the study?
Success rates of traditional endocardial ablation techniques for atrial fibrillation remain modest, though posterior wall ablation combined with PVI may improve outcomes.
Observational (n=52)
No
The Navik 3D mapping system facilitates successful cryoballoon pulmonary vein isolation and left atrial debulking with acceptable procedure and fluoroscopy times.
Answers are grounded in this paper and cite their sources.
May improve AF ablation success with cryoballoon posterior wall isolation; leaves open efficacy in randomized trials.
The success rates of traditional endocardial ablation techniques for managing atrial fibrillation remain modest. Recently, the performance of posterior wall ablation in conjunction with pulmonary vein (PV) isolation (PVI) has been reported to increase the chance of success following endocardial ablation. We report a systematic approach for the isolation of the PVs and ablation of the left atrial roof and posterior wall using a cryoballoon guided by the novel Navik 3D™ mapping system (APN Health LLC, Waukesha, WI, USA) and offer preliminary data including procedure, fluoroscopy, and cryoablation times for review. Patients (n = 52) aged 63 years ± 10 years with paroxysmal (n = 42), persistent (n = 11), or chronic (n = 2) atrial fibrillation underwent cryoballoon ablation for PVI and/or the left atrial roof, posterior wall, anterior ganglion plexi (GP), or mitral isthmus line. Lesions were accurately delivered to the PVs, left atrial roof, posterior wall, anterior GP, or mitral isthmus line as appropriate. Acute PVI was achieved in 98% of all patients, and eight (15%) required direct current cardioversion to restore sinus rhythm at the end of the procedure. The mean ± standard deviation procedure, fluoroscopy, and cryoballoon ablation times were 149 minutes ± 39 minutes, 33 minutes ± 30 minutes, and 41 minutes ± 14 minutes, respectively. The Navik 3D™ mapping system is believed to be the only available mapping system that allows for the visualization and location of the cryoballoon in three dimensions, enabling the operator to deliver contiguous, overlapping lesions on the roof and posterior wall of the left atrium. It also facilitates precise measurement of the distance between the esophageal temperature probe and the cryoballoon, thereby helping to avoid freezing damage to the esophagus.
No takes yet. Share an insight, caveat, or question.
Niazi et al. (2020) conducted an observational in Atrial fibrillation (n=52). Cryoballoon ablation using Navik 3D mapping system was evaluated on Acute pulmonary vein isolation. Cryoballoon ablation guided by the Navik 3D mapping system achieved acute pulmonary vein isolation in 98% of patients with atrial fibrillation.