Key result
IVUS-guided drug-coated balloon angioplasty eliminated trans-stenotic gradients, increased RIPV minimum stenotic area from 4.72 to 62.3 mm², and kept the patient symptom-free at 1 year.
Why the study?
In-stent restenosis after percutaneous stenting for AF radiofrequency ablation-related pulmonary vein stenosis is relatively common, but standardized procedures, clinical experience, and specific material for its percutaneous management are lacking.
Case Report (n=1)
No
This case report demonstrates that IVUS-guided drug-coated balloon venoplasty can successfully treat pulmonary vein in-stent restenosis after atrial fibrillation ablation while avoiding a second metallic stent layer.
Answers are grounded in this paper and cite their sources.
May offer stent-sparing option for recurrent pulmonary vein restenosis; hypothesis-generating pending prospective validation.
BACKGROUND: Pulmonary veins stenosis (PVS) after atrial fibrillation radiofrequency ablation is an uncommon complication. When it occurs, percutaneous treatment is the preferred approach. There is a lack of standardized procedures, and when stenting restenosis is relatively common. CASE SUMMARY: We present a young patient with recurrence of PVS after first percutaneous treatment. The recurrence of haemoptysis and dyspnoea after treatment in PVS allowed the diagnosis of significant stenosis again in our patient. In the Heart Team, we opted for a new percutaneous treatment, using intravascular ultrasound (IVUS) to optimize the final result. DISCUSSION: Nowadays, percutaneous approach is preferred and among percutaneous treatments for PVS, stenting has shown better results than balloon angioplasty (BA). Despite this, experience in in-stent restenosis is limited, and there is a lack of adequate and specific material for its approach. In this case, we present the possible role of the IVUS and the drug-coated BA in this entity.
No takes yet. Share an insight, caveat, or question.
Portero‐Portaz et al. (2021) conducted a case report in In-stent restenosis in pulmonary vein stenosis following atrial fibrillation radiofrequency ablation (n=1). Intravascular ultrasound (IVUS)-guided drug-coated balloon (DCB) angioplasty was evaluated on Resolution of hemodynamic gradient, luminal area improvement (minimum stenotic area), and freedom from recurrent symptoms. IVUS-guided drug-coated balloon angioplasty eliminated trans-stenotic gradients, increased RIPV minimum stenotic area from 4.72 to 62.3 mm², and kept the patient symptom-free at 1 year.
Synapse has enriched 10 related papers. Consider them for comparative context: