Answers are grounded in this paper and cite their sources.
The danger of fire is present always and everywhere. The imminent danger depends upon the actual type and length of fire exposure. Reinforced concrete structural members are loadbearing components in buildup structures and are therefore at high risk, since the entire structure might potentially collapse upon their failure. Thus, it is imperative to comprehend the behavior of reinforced concrete members at high temperatures in case of fire. In this study, the mechanical properties of concrete exposed to high temperatures were experimentally determined through the testing of 27 concrete cylinder starting at room temperature and increasing up to 260 °C. The concrete material behavior was implemented into the ABAQUS software and a finite simulation of reinforced concrete beams exposed to actual fire conditions were conducted. The finite element models compared favorably with the available experimental results. Thus, providing a valuable tool that allows for the prediction of failure in case of a fire event.
No takes yet. Share an insight, caveat, or question.
Issa et al. (2021) studied this question.