Why the study?
What are the procedural trends, outcomes, and readmission rates for MitraClip following FDA approval?
Observational (n=2,003)
Yes
What are the procedural trends, outcomes, and readmission rates for MitraClip following FDA approval?
Following FDA approval, MitraClip procedural volumes increased significantly while morbidity and mortality trended downwards, particularly in hospitals performing ≥10 cases per year.
Background There are sparse clinical data on the procedural trends, outcomes and readmission rates following FDA approval and expansion of Transcatheter mitral valve repair/MitraClip®. Whether a complex new technology can be disseminated safely and quickly is controversial. Methods The study cohort was derived from the National Readmission Data (NRD) 2013–14. MitraClip® was identified using appropriate International Classification of Diseases, 9th Revision, Clinical Modification (ICD‐9‐CM) codes. The primary outcome was a composite of in‐hospital mortality + procedural complications. Secondary outcome included 30‐day readmissions. Hierarchical two level logistic models were used to evaluate study outcomes. Results Our analysis included 2003 MitraClip® procedures. Overall in‐hospital mortality was 3.9%. As expected, there was a significant increase in procedural volume post‐FDA approval. Importantly, a corresponding downward trend in mortality and procedural complications was observed. Significant predictors of in‐hospital mortality and procedural complications included the use of vasopressors (P <0.001) and hemodynamic support (P < 0.001). Higher hospital volume (≥10 MitraClips/year) was associated with lower in‐hospital mortality and complications (P = 0.02). There were 304 (15.1%) 30‐day readmissions, with heart failure being the most common cause of readmission. Elective procedures had lower in‐hospital mortality (P < 0.001) and lower readmission rates (P = 0.011) compared with nonelective procedures. Conclusion A significant increase in MitraClip® procedural volumes occurred post‐FDA approval. Overall morbidity and mortality were low and trended downwards. Hospital procedure volume ≥10 cases were associated with lower mortality and overall complication rates. These data suggest a successful roll out of a very complex novel structural heart procedure.
No takes yet. Share an insight, caveat, or question.
Panaich et al. (2017) conducted an observational in Transcatheter mitral valve repair (n=2,003). MitraClip was evaluated on Composite of in-hospital mortality + procedural complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: