Key result
Two-dimensional transthoracic echocardiography using the biplane Simpson's method strongly correlated with pericardiocentesis-derived pericardial effusion volume (r = +0.823, P < 0.001).
Why the study?
Does two-dimensional transthoracic echocardiography using the biplane Simpson's method accurately estimate pericardial effusion volume compared to actual drained volume in patients undergoing pericardiocentesis?
Observational (n=33)
Does two-dimensional transthoracic echocardiography using the biplane Simpson's method accurately estimate pericardial effusion volume compared to actual drained volume in patients undergoing pericardiocentesis?
Two-dimensional transthoracic echocardiography using the biplane Simpson's method provides an accurate, quantitative estimation of pericardial effusion volume that correlates strongly with actual drained volume.
Answers are grounded in this paper and cite their sources.
Biplane Simpson's method correlates strongly with drained volume; supports quantitative over semiquantitative PE assessment but leaves adoption open pending prospective data.
BACKGROUND: Pericardial effusion (PE) volume is often assessed semiqualitatively by echocardiography and categorized into minimal, small, moderate, or large. Several methods of echocardiographic quantification have been proposed, but their application is limited either by complexity or inaccuracy. We evaluated the accuracy of PE volume quantification by two-dimensional transthoracic echocardiogram (2DTTE) and commercially available volume quantification software in patients undergoing pericardiocentesis. METHODS: In a retrospective case series, immediate preprocedure echocardiograms of 33 patients for pericardiocentesis were analyzed. 2DTTE using the Simpson's method was adopted for volume measurement in the apical two- and four-chamber views. Pericardial fluid volume was calculated by taking the difference between volumes obtained by tracing the epicardial border of the heart and the pericardium. Postprocedure echocardiograms were performed to verify adequate pericardiocentesis. RESULTS: The mean pericardiocentesis fluid volume was 725.1 ± 299.5 mL (range, 250-1420 mL). The average volume estimated echocardiographically by the Simpson's method was 657.5 ± 276.9 mL (range, 205.7-1193.2 mL). There was strong direct linear correlation between echocardiographic and pericardiocentesis-derived volumes (P < 0.001, r = +0.823). Echocardiography underestimated PE volume by a mean of 9.3%. CONCLUSION: Two-dimensional transthoracic echocardiography using biplane Simpson's method of disks can simply and accurately estimate PE volume.
No takes yet. Share an insight, caveat, or question.
Khosraviani et al. (2014) conducted an observational in Pericardial effusion (n=33). Two-dimensional transthoracic echocardiogram (2DTTE) using the Simpson's method vs. Pericardiocentesis-derived volume was evaluated on Correlation between echocardiographic and pericardiocentesis-derived volumes (r = +0.823, p=< 0.001). Two-dimensional transthoracic echocardiography using the biplane Simpson's method strongly correlated with pericardiocentesis-derived pericardial effusion volume (r = +0.823, P < 0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: