Key result
The RT-iiPCR assay detected Rotavirus Group A in 56.9% of samples, compared to 51.4% by commercial rtRT-PCR, 36.7% by in-house rtRT-PCR, 31% by EM, and 29.4% by ELISA.
Why the study?
Does the RT-iiPCR assay provide sensitive and specific on-site detection of Rotavirus Group A compared to standard laboratory methods in diarrheic animals?
Cross-Sectional (n=108)
Does the RT-iiPCR assay provide sensitive and specific on-site detection of Rotavirus Group A compared to standard laboratory methods in diarrheic animals?
The RT-iiPCR system is a sensitive, user-friendly, and field-deployable method for on-site detection of Rotavirus Group A in animals.
Answers are grounded in this paper and cite their sources.
RT-iiPCR may increase Rotavirus detection sensitivity in clinical samples; hypothesis-generating and requires validation of specificity and outcomes before adoption.
There is no gold standard for detection of Rotavirus Group A (RVA), one of the main causes of diarrhea in neonatal animals. Sensitive and specific real-time RT-PCR (rtRT-PCR) assays are available for RVA but require submission of the clinical samples to diagnostic laboratories. Patient-side immunoassays for RVA protein detection have shown variable results, particularly with samples from unintended species. A sensitive and specific test for detection of RVA on the farm would facilitate rapid management decisions. The insulated isothermal RT-PCR (RT-iiPCR) assay works in a portable machine to allow sensitive and specific on-site testing. The aim of this investigation was to evaluate a commercially available RT-iiPCR assay for RVA detection in feces from different animal species. This assay was compared to an in-house rtRT-PCR assay and a commercially available rtRT-PCR kit, as well as an ELISA and EM for RVA detection. All three PCR assays targeted the well-conserved NSP5 gene. Clinical fecal samples from 108 diarrheic animals (mainly cattle and horses) were tested. The percentage of positive samples by ELISA, EM, in-house rtRT-PCR, commercial rtRT-PCR, and RT-iiPCR was 29.4%, 31%, 36.7%, 51.4%, 56.9%, respectively. The agreement between different assays was high (81.3-100%) in samples containing high viral loads. The sensitivity of the RT-iiPCR assay appeared to be higher than the commercially available rtRT-PCR assay, with a limit of detection (95% confidence index) of 3-4 copies of in vitro transcribed dsRNA. In conclusion, the user-friendly, field-deployable RT-iiPCR system holds substantial promise for on-site detection of RVA.
No takes yet. Share an insight, caveat, or question.
Soltan et al. (2016) conducted a cross-sectional in Rotavirus Group A (RVA) infection (n=108). RT-iiPCR assay vs. ELISA, EM, in-house rtRT-PCR, and commercial rtRT-PCR was evaluated on Percentage of positive samples for Rotavirus Group A. The RT-iiPCR assay detected Rotavirus Group A in 56.9% of samples, compared to 51.4% by commercial rtRT-PCR, 36.7% by in-house rtRT-PCR, 31% by EM, and 29.4% by ELISA.
Synapse has enriched 10 related papers. Consider them for comparative context: