Answers are grounded in this paper and cite their sources.
Real-time observations of film stress are presented from three growths of strained InGaAs/GaAs layers. The initial metastable growth regime is analyzed to extract the alloy compositions of x=0.136, 0.155, and 0.180. The strain values at the end of the growths (thicknesses 0.791, 1.08, and 0.115 μm, respectively) are then used to deduce the amounts of relaxation γ=0.808, 0.857, and 0.261, respectively. These data obtained from the in situ optical stress sensor are compared with conventional measurements using asymmetric x-ray diffraction. The agreement is good, within 4%–6% for composition, indicating that the in situ sensor is suitable for quantitative study of strain relaxation during film growth.
No takes yet. Share an insight, caveat, or question.
Beresford et al. (2001) studied this question.