Answers are grounded in this paper and cite their sources.
Multi-institutional observer study demonstrates visual steatosis estimates exceed AI measurements by up to 3.6-fold in liver biopsies, highlighting the need for standardized quantification methods.
Aims Despite its clinical importance, histological steatosis assessment remains poorly standardized and highly variable among pathologists. We examined determinants of this variability by comparing pathologist estimates with quantitative artificial intelligence (AI) based measurements. Methods and Results Ten experienced liver pathologists from four institutions evaluated a limited set of 20 permanent H&E‐stained whole‐slide images (WSIs) from metabolic dysfunction‐associated steatotic liver disease (MASLD) cases (10 core biopsies, 7 wedge biopsies and 3 resections) and 6 additional 500 × 500‐μm image fields from separate permanent H&E‐stained cases selected to represent varying droplet compositions. The WSIs spanned the full spectrum of steatosis severity. Assessments used four phases: default method, steatosis proportionate area (SPA), percentage of hepatocytes containing fat (%HCF) and Banff large‐droplet criteria. Image fields were also assessed using no size cut‐off or cut‐offs based on hepatocyte, nuclear or 2–3× nuclear size. AI models quantified SPA, %HCF and droplet size for comparison with pathologists' assessments. Pathologists differed substantially in terminology, droplet‐size definitions and quantification methods. Method choice (SPA vs. %HCF) was a major determinant of estimate dispersion and discrepancy from AI measurements. Visual estimates exceeded AI quantification by 1.4–3.6×. Pathologists' SPA estimates were increasingly higher than the corresponding AI measurements with increasing burden of droplets with area below 50 μm 2 , whereas, in exploratory analysis, %HCF estimates remained relatively stable relative to the corresponding AI measurements. Mixed‐effects calibration equations were derived to relate visual and digital assessment scales. Conclusion Steatosis assessment lacks standardized terminology and measurement practices. SPA and %HCF are conceptually distinct, and their interchangeable use amplifies discrepancies, particularly in small‐droplet‐rich cases. These findings support standardized, AI‐compatible quantification; the exploratory conversion equations require independent validation before clinical application.
No takes yet. Share an insight, caveat, or question.
Nazli et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: