Answers are grounded in this paper and cite their sources.
This report presents preliminary case studies of the performance of selected unreinforced masonry buildings during the Whittier Narrows Earthquakes. Attention is focused on buildings located in the downtown Los Angeles area which have been rehabilitated to conform with the Los Angeles hazard reduction Ordinance. There was no life loss or major injuries attributed to the response of unreinforced masonry buildings to the earthquakes. However, there was a significant number of both rehabilitated and non‐strengthened buildings for which masonry peeled off upper story walls. This was mainly due to separation of the outer whythe of brick, or out‐of‐plane bending failure, and/or in‐plane shear failures of wall piers, particularly at building corners. The falling bricks associated with these failures did present an injury hazard so it is important to investigate economical measures to minimize these hazards in future earthquakes.
No takes yet. Share an insight, caveat, or question.
Moore et al. (1988) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: