Key result
The proposed HR-WPD and time-attention CNN algorithm achieved high QRS detection accuracy, with F1-scores of 97.25% on TELEDB, 97.76% on NSTDB, and 99.89% on ARRDB.
Why the study?
ECG collected by wearable devices requires a robust QRS detection algorithm that maintains high accuracy despite severe noise and abnormal QRS morphologies.
Does a QRS detection algorithm using HR-WPD and time-attention CNN improve detection accuracy in noisy ECGs compared to existing methods?
Does a QRS detection algorithm using HR-WPD and time-attention CNN improve detection accuracy in noisy ECGs compared to existing methods?
The proposed HR-WPD and time-attention CNN algorithm provides highly accurate and robust QRS detection, making it suitable for analyzing noisy ECG data from wearable devices.
Supports wearable QRS detection in noise; extends CNN methods but leaves open clinical validation.
QRS detection is a crucial step in analyzing the electrocardiogram (ECG). For ECG collected by wearable devices, a robust QRS detection algorithm that yields high accuracy in spite of abnormal QRS morphologies and severe noise is needed. In this paper, we propose a QRS detection method based on high-resolution wavelet packet decomposition (HR-WPD) and convolutional neural network (CNN). Firstly, we design the HR-WPD that decomposes the ECG into multiple signals with different frequency bands to provide detailed QRS features. Secondly, all the decomposed signals are forwarded to a CNN for comprehensive morphology analysis and QRS prediction. To further improve the robustness, a time-attention module acting on the input signals is added to the CNN. Finally, a variable threshold is imposed to locate the QRS. The proposed method is validated by using two noisy databases (i.e., Telehealth Database (TELEDB) and MIT-BIH Noise Stress Test Database (NSTDB)) and one database with multiple ECG morphologies (i.e., MIT-BIH Arrhythmia Database (ARRDB)). The experiment results show that the proposed method achieves a comparable or even better performance compared with state-of-art methods on the TELEDB (SE 98.99%, P+ 95.57%, ER 5.61%, F1 97.25%), NSTDB (SE 99.25%, P+ 96.31%, ER 4.55%, F1 97.76%) and ARRDB (SE 99.89%, P+ 99.90%, ER 0.21%, F1 99.89%), suggesting that it is highly applicable to the QRS detection for ECG collected by wearable devices.
No takes yet. Share an insight, caveat, or question.
Jia et al. (2020) studied Electrocardiogram (ECG) QRS detection (n=313). High-resolution wavelet packet decomposition and time-attention convolutional neural network vs. State-of-the-art QRS detection methods was evaluated on QRS detection performance (F1-score). The proposed HR-WPD and time-attention CNN algorithm achieved high QRS detection accuracy, with F1-scores of 97.25% on TELEDB, 97.76% on NSTDB, and 99.89% on ARRDB.