Key result
The ISTH-BAT effectively assessed bleeding in platelet function defects, yielding 100% sensitivity and 76.2% specificity, similar to the electronic bleeding questionnaire.
Why the study?
Does the ISTH-BAT accurately assess bleeding phenotype compared to eBQ in patients with Glanzmann's thrombasthenia and Bernard-Soulier syndrome?
Observational (n=48)
Does the ISTH-BAT accurately assess bleeding phenotype compared to eBQ in patients with Glanzmann's thrombasthenia and Bernard-Soulier syndrome?
Both ISTH-BAT and eBQ are efficient in assessing bleeding phenotypes in Bernard-Soulier syndrome and Glanzmann's thrombasthenia, supporting the ISTH recommendation to adopt ISTH-BAT.
Answers are grounded in this paper and cite their sources.
May support ISTH-BAT for bleeding phenotyping in Glanzmann's and Bernard-Soulier; leaves open prospective validation.
The main objective of this study is to investigate the utility of International Society on Thrombosis and Haemostasis-Bleeding Assessment Tool (ISTH-BAT) in comparison with the condensed form of Molecular and Clinical Markers for the Diagnosis and Management of type 1 and WHO BATs, in assessing bleeding in two well known and clinically significant platelet function defects. Thirty-eight patients previously diagnosed with Glanzmann's thrombasthenia and 10 with Bernard-Soulier syndrome (BSS) were analyzed. Bleeding scores were significantly higher than that of controls using both electronic bleeding questionnaire (eBQ) and ISTH-BAT with no significant difference between both tools. ISTH-BAT had a sensitivity, specificity, positive predictive value and negative predictive value of 100%, 76.2%, 0.9 and 1. This was closely similar to eBQ. Both ISTH-BAT and eBQ are efficient in BSS and Glanzmann's thrombasthenia. However, given the ISTH recommendation, ISTH-BAT should be adopted. Larger study including other platelet defects will enhance its utility and support the integration of bleeding scores with standardized laboratory testing to allow for a universal diagnostic approach to patients with suspected bleeding disorders.
No takes yet. Share an insight, caveat, or question.
Kaur et al. (2016) conducted an observational in Glanzmann's thrombasthenia and Bernard-Soulier syndrome (n=48). International Society on Thrombosis and Haemostasis-Bleeding Assessment Tool (ISTH-BAT) vs. electronic bleeding questionnaire (eBQ) and controls was evaluated on Diagnostic accuracy (sensitivity, specificity, PPV, NPV). The ISTH-BAT effectively assessed bleeding in platelet function defects, yielding 100% sensitivity and 76.2% specificity, similar to the electronic bleeding questionnaire.
Synapse has enriched 10 related papers. Consider them for comparative context: