Clinical commentary observes preshaped Simmons guiding sheaths enhance carotid cannulation during transradial neurointerventions, highlighting technical strategies for steep vascular takeoffs.
To the Editor: We read with great interest the study entitled “Lessons Learned After 760 Neurointerventions via the Upper Extremity Vasculature: Pearls and Pitfalls” by Sweid et al.1 We completely agree with the authors’ conclusion that transradial access (TRA) is a safe and effective way of performing various neuroendovascular procedures associated with excellent clinical outcomes and an overall low rate of periprocedural complications. The authors have documented inherent limitations of the TRA approach, which become more evident in therapeutic procedures, especially with the current lack of radial-specific catheters.1 TRA can be technically challenging in patients with an unfavorable steep takeoff of the target common carotid artery (CCA), including those with right CCA lesions with steep angulation to the right subclavian artery via right TRA or those with nonbovine left CCA lesions via right or left TRA.1-4 In such cases, a conventional “straight-shaped” guiding system can herniate into the aortic arch and/or can lead to catheter kinking. We have employed TRA as the first-line approach—a radial-first strategy—for therapeutic neurointerventions, including anterior circulation interventions.2-8 We previously described that the first-line TRA with a 6F “preshaped” Simmons guiding sheath (2.70 mm outer diameter, 0.088 inch inner diameter, 6F Axcelguide Stiff-J, 90 cm; Medikit, Tokyo, Japan) provides a large-bore working channel and a high procedural success rate without catheter kinking or system instability, regardless of the aortic arch type, target CCA, and access side.2-4 The 6F Simmons guiding sheath is a radial-specific neurointerventional sheathless guiding catheter especially designed for CCA cannulation. Based on the target CCA and access side, the push-in or pull-back technique is used for CCA cannulation.2-4 The push-in technique is a procedure to coaxially advance a 6F Simmons guiding sheath with a push-in maneuver. The pull-back technique, which is technically straightforward and unique to this radial-specific neurointerventional guiding sheath, is a procedure to coaxially deliver a 6F Simmons guiding sheath with a pull-back maneuver after the re-formation of the natural reversed curve (Simmons curve) within the ascending aorta. To reform the Simmons curve, the descending aorta anchoring technique (DAT) or subclavian artery anchoring technique (SCAT) is used based on the aortic arch type and access side.2-4 The DAT is a procedure in which the descending aorta is used as the anchor for re-forming the Simmons curve, whereas the SCAT is a procedure in which the contralateral subclavian artery is used as the anchor for re-forming the Simmons curve. The push-in technique is primarily used for patients with favorable trajectories via right TRA, including most right CCA lesions or bovine left CCA lesions. The pull-back technique is effective, especially for patients with the aforementioned challenging conditions. We believe that a sheathless system using the radial-specific 6F Simmons guiding sheath provides a useful therapeutic option in anterior circulation interventions via TRA. Finally, we want to congratulate the authors for their interesting study, which contributes to the advancement of the transradial neurointerventional approach. This study did not receive any funding or financial support. The authors have no personal, financial, or institutional interest in any of the drugs, materials, or devices described in this article.
No takes yet. Share an insight, caveat, or question.
Hanaoka et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: