Answers are grounded in this paper and cite their sources.
We hypothesized that early bone adaptation to well fixed porous-coated implants is influenced more by wound healing than by mechanical loading. To test this hypothesis, two groups of dogs with identical, hydraulically controlled porous-coated implants interference fit within distal femoral trabecular bone were used. One group had no load: the other had 35 N of load applied to the implants. At 5 weeks after surgery, the resulting adaptation of bone around the implants was quantified on a cellular basis by cytochemical analysis of type-I procollagen synthesis and on a structural basis using three-dimensional micro-computed tomography imaging. The percentage of trabecular surfaces covered by osteoblasts expressing type-I procollagen was significantly increased in bone surrounding the implant in both groups compared with contralateral control bone tissue. There was no difference between the groups with no load or 35 N of load. In addition, measures of trabecular bone structure did not differ significantly between the load and no-load groups. Taken together, these results suggest that wound healing plays a much greater role in the early response of bone to well fixed porous-coated implants than does mechanical stimulus.
No takes yet. Share an insight, caveat, or question.
Hollister et al. (1996) studied this question.