Answers are grounded in this paper and cite their sources.
In the present study we compared measurements of vessel lengths from (a) single-digital scanning electron microscope (SEM) images of microvascular corrosion casts (VCCs) of gill filters of tadpoles of Xenopus laevis Daudin by two-dimensional (2-D) morphometry (Optimas 6.5, Optimas Corp., Bothell, Wash., USA; planar measurements) and (b) digital stereopairs by three-dimensional (3-D) morphometry (3D-Morphometry, Minnich and Muska OEG, Salzburg). Depending on the spatial orientation of the vessels measured, we found a maximum difference of 58.84% (100 [3-D]-41.16 [2-D]) in vessel lengths by 3-D morphometry versus 2-D morphometry, which, in multiple (segmental) lengths measurements or when determining space angles, might be even higher. Based on results we consider 3-D morphometry of VCCs to be the method of choice for lengths measurements.
No takes yet. Share an insight, caveat, or question.
Minnich et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: