Measurements have been made of time-dependent saturation ion currents flowing to a probe and to the discharge electrodes following the forced extinction of high-current (1–5 kA) vacuum arcs of short duration (≃1 ms) on copper electrodes.The results have been utilised to derive ion-flux distributions irrespective of ion-charge number, assuming collisionless plasma expansion from the cathode spots, and significant differences have been found compared with previous measurements on steady-state discharges.The results on interrupted and steady-state discharges are reconcilable if a source of low-energy ions exists, which is constrained in the cathode-spot region in the steady state and which is released at the zero current condition when the constraining forces vanish.
No takes yet. Share an insight, caveat, or question.
Bauer et al. (1977) studied this question.