Answers are grounded in this paper and cite their sources.
In this study, a numerical model is developed to simulate the xenon plasma plume from a thermionic hollow cathode employing an orifice plate used for propellant ionization and beam neutralization in an electrostatic space propulsion system. The model uses a detailed fluid model to describe the electrons and a particle-based kinetic approach is used to model the heavy xenon ions and atoms. A number of key assumptions in terms of physical modeling and boundary conditions of the simulations are assessed through direct comparisons with experimental measurements. For two of the three cathode operating conditions considered, good agreement with the measured data is obtained. The third condition appears to lie in a different physical regime where elevated electron and ion temperatures and decreased transport coefficients are required in the simulation to provide agreement between the model and the measured data.
No takes yet. Share an insight, caveat, or question.
Boyd et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: