Key result
Insufficient endocardial lead length (OR 3.914) and excessive lead length (OR 2.595) on chest X-ray were significantly associated with severe tricuspid regurgitation.
Why the study?
Does non-optimal radiological endocardial lead position increase the risk of severe tricuspid regurgitation in patients with cardiac stimulation systems?
Cross-Sectional (n=100)
No
Does non-optimal radiological endocardial lead position increase the risk of severe tricuspid regurgitation in patients with cardiac stimulation systems?
Non-optimal radiological positioning of endocardial leads, particularly insufficient or excessive lead length, is strongly associated with the presence of severe tricuspid regurgitation.
ENWEndNote BIBJabRef, Mendeley RISPapers, Reference Manager, RefWorks, Zotero AMA Rydlewska A, Ząbek A, Boczar K, Lelakowski J, Małecka B. Tricuspid valve regurgitation in the presence of endocardial leads – an underestimated problem. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej. 2017;13(2):165-169. doi:10.5114/pwki.2017.68073. APA Rydlewska, A., Ząbek, A., Boczar, K., Lelakowski, J., & Małecka, B. (2017). Tricuspid valve regurgitation in the presence of endocardial leads – an underestimated problem. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej, 13(2), 165-169. https://doi.org/10.5114/pwki.2017.68073 Chicago Rydlewska, Anna, Andrzej Ząbek, Krzysztof Boczar, Jacek Lelakowski, and Barbara Małecka. 2017. "Tricuspid valve regurgitation in the presence of endocardial leads – an underestimated problem". Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej 13 (2): 165-169. doi:10.5114/pwki.2017.68073. Harvard Rydlewska, A., Ząbek, A., Boczar, K., Lelakowski, J., and Małecka, B. (2017). Tricuspid valve regurgitation in the presence of endocardial leads – an underestimated problem. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej, 13(2), pp.165-169. https://doi.org/10.5114/pwki.2017.68073 MLA Rydlewska, Anna et al. "Tricuspid valve regurgitation in the presence of endocardial leads – an underestimated problem." Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej, vol. 13, no. 2, 2017, pp. 165-169. doi:10.5114/pwki.2017.68073. Vancouver Rydlewska A, Ząbek A, Boczar K, Lelakowski J, Małecka B. Tricuspid valve regurgitation in the presence of endocardial leads – an underestimated problem. Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej. 2017;13(2):165-169. doi:10.5114/pwki.2017.68073.
No takes yet. Share an insight, caveat, or question.
Rydlewska et al. (2017) conducted a cross-sectional in Cardiac stimulation system implantation (n=100). Insufficient endocardial lead length vs. Optimal lead position was evaluated on Severe tricuspid regurgitation (OR 3.914, p=0.003). Insufficient endocardial lead length (OR 3.914) and excessive lead length (OR 2.595) on chest X-ray were significantly associated with severe tricuspid regurgitation.