Key result
A newly designed curved stainless steel probe guide facilitates the rapid and less traumatic insertion of catheters into small vessels in pediatric patients.
Why the study?
Does the use of a curved probe guide facilitate catheter insertion in small vessels in pediatric patients?
Does the use of a curved probe guide facilitate catheter insertion in small vessels in pediatric patients?
Answers are grounded in this paper and cite their sources.
A novel curved probe guide simplifies and accelerates the insertion of catheters into small vessels in pediatric patients while minimizing vessel trauma.
THE INTRODUCTION of a catheter into a vein or artery in the pediatric age group is often difficult because of the small size of the vessels. A guide is herein described which greatly facilitates the insertion of a catheter. This instrument both dilates the vessel and guides the placement. The guide is a curved probe tapering to a point, with a groove on its underside and a phlange on one end to facilitate its manipulation (Fig. 1, A). It is fashioned from 23 gauge. #316 stainless steel. Several sizes are made for the various sized catheters. The inside diameters of the guide vary from ⅛ to 3/64 of an inch and the length is 1½ inches. The phlange measures 1 by ¾ inches. The technique of catheter introduction is as follows: a small longitudinal incision is made in a previously isolated vessel, the pointed end of the guide is then inserted and threaded up the vessel for a distance of two to eight millimeters. With one hand holding the guide in place, the catheter is slipped along the groove in the underside of the guide and into the vessel (Fig. 1, B). Once the catheter is in place, the guide is withdrawn. Advantages of the guide are its structural simplicity and the speed with which [SEE FIG I IN SOURCE PDF] catheters can be inserted or replaced. No forceps or hemostats are needed. Catheters can now be readily inserted into small vessels. There is little trauma to the vessel aside from the initial incision. The latter becomes important when vessels are repaired following catheterization. Such is the case for all retrograde arterial catheterizations. In addition to its use during cardiac catheterization, the guide should make easy the insertion of plastic tubing for exchange transfusion and in exposure of veins for intravenous therapy, especially in infants.
No takes yet. Share an insight, caveat, or question.
Hohn et al. (1959) studied Catheterization of small vessels. Curved stainless steel probe guide was evaluated. A newly designed curved stainless steel probe guide facilitates the rapid and less traumatic insertion of catheters into small vessels in pediatric patients.
Synapse has enriched 10 related papers. Consider them for comparative context: