Key result
Biplane double supported screw fixation (BDSF) for femoral neck fractures resulted in 80% of patients achieving excellent or good clinical outcomes.
Why the study?
Fractures of the neck of femur present a challenge requiring adequate reduction and stable fixation, prompting the evaluation of cannulated cancellous screw fixation using the BDSF method.
Does the biplane double supported screw fixation (BDSF) method yield favorable outcomes in patients with femoral neck fractures?
Observational (n=25)
No
Does the biplane double supported screw fixation (BDSF) method yield favorable outcomes in patients with femoral neck fractures?
The BDSF method for femoral neck fractures yields excellent or good results in 80% of patients, providing a viable fixation strategy.
BDSF may yield favorable femoral neck fracture outcomes; leaves open comparative efficacy versus standard fixation in RCTs.
Introduction: Fracture neck of femur has always presented a great challenge to the Orthopaedic surgeons. Results depend upon adequacy of reduction and stable fixation. Fixation with cannulated cancellous screws is usually adequate for femoral neck fractures. The aim of the study was to analyze the results of treatment of fracture neck of femur with cannulated cancellous screw fixation using BDSF method.Materials and Methods: This prospective study was carried out in the postgraduate Department of Orthopaedics, Govt. Bone and Joint Hospital, an associated hospital of Govt. Medical College Srinagar from 2019-2021. A total of 25 patients who presented in the department with femoral neck fractures and qualified the inclusion criteria were included in the study.Results: Among 25 patients 12 (48%) patients achieved excellent results, 8 (32%) patients achieved good results, 3 (12%) patients achieved fair results and 2 (8%) patients achieved poor results. 80% of the patients achieved either excellent or good result.Conclusion: BDSF is a novel method of fixation of femoral neck fractures, associated with higher axial fixation strength and union rate compared to conventional fixation methods. It employs bi-plane positioning of three cannulated screws placed at steeper angles to the diaphyseal axis.
No takes yet. Share an insight, caveat, or question.
Dar et al. (2023) conducted an observational in Femoral neck fractures (n=25). Biplane double supported screw fixation (BDSF) was evaluated on Excellent or good clinical results. Biplane double supported screw fixation (BDSF) for femoral neck fractures resulted in 80% of patients achieving excellent or good clinical outcomes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: