[Purpose] Investigation of intra- and inter- measurer errors employing a scapular position measurement method using a tape measure designed by us. [Methods] Two measurers, a physical therapist (RPT) and a student on a physical therapist training course (PTS), measured the scapular position relative to the spine twice using a tape measure, and intra- and inter- measurer measurement errors were investigated. For statistical analysis, Bland-Altman analysis was employed. The limits of agreement (LOA) were determined when a systematic error was present, and the 95% confidence interval of the minimal detectable change (MDC95) was calculated when no systematic error was detected. The significance level was chosen as 5%. [Results] Regarding intra- measurer measurement error, the mean value of the second measurement was greater than that of the first. Regarding inter- measurer error, the mean value measured by PTS was lower than that measured by RPT. [Conclusion] The mean of the first measurement was greater than that of the second measurement as the intra- measurer measurement error of this measurement method, and the mean measured by PTS was lower than that measured by RPT, showing a fixed error. By sufficiently practicing the measurement and applying markers to the bone index points, the measurement error may become small enough to be clinically acceptable.
No takes yet. Share an insight, caveat, or question.
Yoshida et al. (2011) studied this question.