A scheme for the identification of explosive residues from post-explosion scenes is described. The first step consists of organic and inorganic extractions rather than microscopic examination. The methods of identification which follow include thin layer and gas-liquid chromatography, infrared and ultraviolet spectroscopy, and chemical tests. The system, which has been used routinely by the Israel Police for 5 years, deals efficiently with standard military explosives as well as with home-made, improvised mixtures.
No takes yet. Share an insight, caveat, or question.
Kaplan et al. (1977) studied this question.